Transducer laboratory

Transducer laboratory

7728-80

Artikel-Nr. 96524080|EAN 4018754239429

    Produkt-Varianten

    Product no.SizeDisplay deviation +- 0.25% of measuring value N·mDisplay deviation +- 0.5% of measured value N·mDisplay deviation +- 0.5% of measured value ft·lbDisplay deviation +- 0.5% of measured value in·lbMA N·mNominal value N·mdInternal square [inch]WeightWeight with box
    9652400111-100,74-7,48,9-88,51 N·m10 N·m120 mm1/4 "1735 g2415 g
    Jetzt entdecken
    9652400222-201,5-1518-1772 N·m20 N·m120 mm1/4 "1735 g2415 g
    Jetzt entdecken
    9652400444-403-3035-3544 N·m40 N·m120 mm3/8 "2486 g3136 g
    Jetzt entdecken
    9652400666-604,5-4553-5316 N·m60 N·m120 mm3/8 "2486 g3136 g
    Jetzt entdecken
    965240101020-10010-1007-7489-88510 N·m100 N·m120 mm3/8 "2486 g3136 g
    Jetzt entdecken
    965240111S1-100,74-7,48,9-88,51 N·m10 N·m120 mm1/4 "1735 g2415 g
    Jetzt entdecken
    965240202040-20020-20015-148177-177020 N·m200 N·m120 mm1/2 "2983 g3170 g
    Jetzt entdecken
    965240404080-40040-40030-295354-354040 N·m400 N·m156 mm3/4 "4846 g5507 g
    Jetzt entdecken
    9652406565130-65065-65048-479575-575365 N·m650 N·m156 mm3/4 "4846 g5507 g
    Jetzt entdecken
    9652408080160-80080-80059-590708-708180 N·m800 N·m156 mm3/4 "4846 g5507 g
    96524100100200-1000100-100074-738885-8851100 N·m1,000 N·m156 mm3/4 "4846 g5507 g
    Jetzt entdecken
    96524300300600-3000300-3000221-22142655-26553300 N·m3,000 N·m195 mm1 1/2 "10500 g12000 g
    Jetzt entdecken

    Technologien und Leistungsmerkmale

    QuickRelease

    The QuickRelease safety lock prevents unintentional loss of insert tools. These click securely into place, and are only released again at the push of a button for a quick tool change.

    DAkkS calibration certificate

    Our torque tools, transducers and test equipment have an official, internationally recognised calibration certificate in accordance with the requirements of DIN EN ISO/IEC 17025:2018 for the traceability by our in-house DAkkS-accredited calibration laboratory.

    Eigenschaften

      • patented
      • for laboratory environments
      • with optimised measuring range
      • for calibrating torque wrenches and torque screwdrivers
      • for use together with perfectControl® calibrating unit No 7794 or calibration system No 7706
      • high degree of accuracy thanks to conversion and digitization of readings within the transducer itself
      • with high-grade self-locking precision plug
      • not susceptible to lateral forces due to low-profile construction
      • with DAkkS calibration certificate
      • max. display deviation value ± 0.5% of the reading
      • further details on request
      • supplied in sturdy plastic box

    Downloads

    Flyer: 91973048-stahlwille-br-kalibrierkonzept-en-web.pdf
    PDF | 8.08 MB
    Produktdatenblatt: STAHLWILLE_96524080_7728-80_en.pdf
    PDF | 1.11 MB
    Konformitaetserklaerung: EU-Konformitaetserklaerung_CE_UKCA_772x_MeKo-vb.pdf
    PDF | 0.17 MB
    In unserem Kundenportal bieten wir weitere Informationen und Downloads.

    Zubehör-Artikel.

    Newsletter